Cody the heat pump troubleshooting assistantERROR CODESHEAT PUMP
EN
Home › Brands › Atlantic

All Atlantic error codes

This page gathers Atlantic error codes sorted by failure type: what each code means, its likely causes, and what you can safely check before calling a professional.
Can’t find your Atlantic code in the list?
Describe your issue to Cody. It identifies the code, tells you what’s happening, and what you can check yourself. If it doesn’t know the code, it looks it up in the manufacturer’s documentation.

Ask Cody ›

Find your code quickly

The Atlantic codes on this page, grouped by failure type.

Temperature sensor — Atlantic

These codes indicate a sensor that’s no longer returning a consistent value. The issue almost always comes from the sensor itself or its connector, rarely from the unit.

Code 10 FlashesInformationair-to-water
P.F.C. radiator temperature sensor error — diodes / LED
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 13Medium severityair-to-water
Condenser temperature sensor fault
Possible causes
  • Faulty condenser thermistor
  • Loose connection
  • Short circuit
What you can check
  • Turn off power for 30 min, then restart
Affected models: Alfea Excellia, Alfea Extensa
This issue requires a qualified technician. Do not open the unit.
Code 13 FlashesInformationair-to-water
Current sensor error (permanent shutdown). — diodes / LED
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 3 FlashesInformationair-to-water
Pressure switch sensor error. — diodes / LED
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 33Informationair-to-water
Heat pump outlet temperature sensor error.
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 4 FlashesInformationair-to-water
Heat exchanger outlet temperature sensor error. — diodes / LED
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 41Informationair-to-air
Room temperature sensor error
Affected models: Takao M2 wall-mounted R32
Code 42Informationair-to-water
Hydraulic module heat exchanger temperature sensor error. — outdoor unit – LED 4 Flashes / 2 Flashes
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 42Informationair-to-air
Outdoor unit heat exchanger average temperature sensor error
Affected models: Takao M2 wall-mounted R32
Code 44Informationair-to-water
Heat pump return temperature sensor error.
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 441Informationair-to-water
Zone 2 sensor not configured (if 2-circuit kit)
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 5 FlashesInformationair-to-water
Intermediate exchanger temperature sensor error. — diodes / LED
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 50Informationair-to-water
DHW temperature sensor.
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 6 FlashesInformationair-to-water
Expansion valve temperature sensor error. — diodes / LED
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 60Informationair-to-water
Room sensor 1.
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 65Informationair-to-water
Room sensor 2.
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 7 FlashesInformationair-to-water
Outdoor temperature sensor error. — diodes / LED
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 73Informationair-to-water
Exchanger temperature sensor error (outlet / center). — outdoor unit – LED 7 Flashes / 3 Flashes
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 73Informationair-to-air
Indoor unit heat exchanger liquid temperature sensor error
Affected models: Takao M2 wall-mounted R32
Code 74Informationair-to-water
Outdoor temperature sensor error. — outdoor unit – LED 7 Flashes / 4 Flashes
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 74Informationair-to-air
Outdoor temperature sensor error
Affected models: Takao M2 wall-mounted R32
Code 75Informationair-to-air
Suction gas temperature sensor error
Affected models: Takao M2 wall-mounted R32
Code 76Informationair-to-air
• 2-way valve temperature sensor error • 3-way valve temperature sensor error
Affected models: Takao M2 wall-mounted R32
Code 77Informationair-to-air
Cold source temperature sensor error
Affected models: Takao M2 wall-mounted R32
Code 78Informationair-to-water
Expansion valve temperature sensor error. — outdoor unit – LED 7 Flashes / 8 Flashes
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 82Informationair-to-air
• Subcooling heat exchanger gas inlet temperature sensor error • Subcooling heat exchanger gas outlet temperature sensor error
Affected models: Takao M2 wall-mounted R32
Code 83Informationair-to-air
Liquid pipe temperature sensor error
Affected models: Takao M2 wall-mounted R32
Code 84Informationair-to-air
Current sensor error
Affected models: Takao M2 wall-mounted R32
Code 86Informationair-to-water
Pressure switch sensor error / Pressure sensor error. — outdoor unit – LED 8 Flashes / 6 Flashes
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 9 FlashesInformationair-to-water
Inverter radiator temperature sensor error. — diodes / LED
Affected models: Alfea Excellia, Alfea Excellia Duo
This fault requires a qualified technician. Do not open the unit.
Code 94Informationair-to-water
Current sensor error. — outdoor unit – LED 9 Flashes / 4 Flashes
Affected models: Alfea Excellia, Alfea Excellia Duo
Code E3Medium severityair-to-air
Abnormal power supply (indoor unit)
Possible causes
  • Voltage below 198 V
  • Voltage above 264 V
  • Faulty electronic component
Affected models: Takao M2, Dojo, Nagano
This repair requires a qualified technician. Do not open the unit.

General fault — Atlantic

These codes don’t point to a specific part: the unit is signaling that an internal safety feature has been triggered.

Code 105Informationair-to-water
Maintenance message.
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 121Informationair-to-water
CC1 outlet temperature not reached.
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 122Informationair-to-water
CC2 outlet temperature not reached.
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 127Informationair-to-water
Anti-legionella temperature not reached.
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 22 FlashesInformationair-to-water
Hydraulic module fault. — diodes / LED
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 23Informationair-to-air
Combination error
Affected models: Takao M2 wall-mounted R32
This repair requires a qualified technician. Do not open the unit.
Code 29Informationair-to-air
Connected unit number error in the wired remote control configuration
Affected models: Takao M2 wall-mounted R32
Code 33Informationair-to-air
Error detecting indoor unit motor power consumption
Affected models: Takao M2 wall-mounted R32
Code 35Informationair-to-air
Manual/auto switch error
Affected models: Takao M2 wall-mounted R32
Code 369Informationair-to-water
External fault (safety device).
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 41Informationair-to-water
Connection error between the hydraulic module and the outdoor unit. — outdoor unit – LED 4 Flashes / 1 Flash
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 44Informationair-to-air
Presence sensor error
Affected models: Takao M2 wall-mounted R32
Code 53Informationair-to-air
Drain pump error
Affected models: Takao M2 wall-mounted R32
Code 54Informationair-to-air
Electric air purifier reverse VDD error
Affected models: Takao M2 wall-mounted R32
Code 57Informationair-to-air
Damper error
Affected models: Takao M2 wall-mounted R32
Code 58Informationair-to-air
Air intake grille error
Affected models: Takao M2 wall-mounted R32
Code 5UInformationair-to-air
Indoor unit error
Affected models: Takao M2 wall-mounted R32
Code 63Informationair-to-air
Inverter error
Affected models: Takao M2 wall-mounted R32
Code 65Informationair-to-air
L terminal tripping error
Affected models: Takao M2 wall-mounted R32
Code 68Informationair-to-water
Outdoor unit magnetic relay error. — outdoor unit – LED 6 Flashes / 8 Flashes
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 77Informationair-to-water
Outdoor unit radiator temperature error. — outdoor unit – LED 7 Flashes / 7 Flashes
Models concerned: Alfea Excellia, Alfea Excellia Duo
Code 94Informationair-to-air
Trip detection
Models concerned: Takao M2 wall-mounted R32
Code A4Informationair-to-water
Outdoor unit pressure error. — outdoor unit – LED 10 Flashes / 4 Flashes
Models concerned: Alfea Excellia, Alfea Excellia Duo
Code J2Informationair-to-air
Branch box error [Multi flexible]
Models concerned: Takao M2 wall-mounted R32

Compressor — Atlantic

The compressor is the most critical and most expensive part. These codes protect the unit by shutting it down before damage occurs: never force repeated restarts.

Code 12 FlashesInformationair-to-water
Compressor temperature protection (permanent shutdown). — diodes / LED
Models concerned: Alfea Excellia, Alfea Excellia Duo
This fault requires a qualified technician. Do not open the unit.
Code 14 FlashesInformationair-to-water
Compressor rotor position detection error (permanent shutdown). — diodes / LED
Models concerned: Alfea Excellia, Alfea Excellia Duo
This fault requires a qualified technician. Do not open the unit.
Code 15 FlashesInformationair-to-water
Compressor startup error (permanent shutdown). — diodes / LED
Models concerned: Alfea Excellia, Alfea Excellia Duo
This fault requires a qualified technician. Do not open the unit.
Code 72Informationair-to-water
Compressor temperature sensor error. — outdoor unit – LED 7 Flashes / 2 Flashes
Models concerned: Alfea Excellia, Alfea Excellia Duo
This fault requires a qualified technician. Do not open the unit.
Code 72Informationair-to-air
Compressor temperature sensor error
Models concerned: Takao M2 wall-mounted R32
Code 8 FlashesInformationair-to-water
Compressor temperature sensor error. — diodes / LED
Models concerned: Alfea Excellia, Alfea Excellia Duo
This fault requires a qualified technician. Do not open the unit.
Code 84Informationair-to-water
Compressor current error. — outdoor unit – LED 8 Flashes / 4 Flashes
Models concerned: Alfea Excellia, Alfea Excellia Duo
This fault requires a qualified technician. Do not open the unit.
Code 95Informationair-to-water
Compressor rotor position error detection. Compressor startup error. — outdoor unit – LED 9 Flashes / 5 Flashes
Models concerned: Alfea Excellia, Alfea Excellia Duo
This fault requires a qualified technician. Do not open the unit.
Code 95Informationair-to-air
Compressor rotor position detection error
Models concerned: Takao M2 wall-mounted R32
This fault requires a qualified technician. Do not open the unit.
Code A3Informationair-to-water
Compressor temperature protection. — outdoor unit – LED 10 Flashes / 3 Flashes
Models concerned: Alfea Excellia, Alfea Excellia Duo
This fault requires a qualified technician. Do not open the unit.
Code A3Informationair-to-air
Compressor temperature error
Models concerned: Takao M2 wall-mounted R32
This fault requires a qualified technician. Do not open the unit.
Code E5Critical severityair-to-air
Safety shutdown triggered by the indoor coil sensor
Possible causes
  • Clogged filter
  • Refrigerant leak
  • Dirty indoor coil
Models concerned: Takao M2, Dojo, Nagano
This fault requires a qualified technician. Do not open the unit.

Fan — Atlantic

The fan expels or draws in heat. If it’s blocked or faulty, pressure rises and triggers a shutdown.

Code 16 FlashesInformationair-to-water
Fan motor 1 error (permanent shutdown). — diodes / LED
Models concerned: Alfea Excellia, Alfea Excellia Duo
Code 17 FlashesInformationair-to-water
Fan motor 2 error (permanent shutdown). — diodes / LED
Models concerned: Alfea Excellia, Alfea Excellia Duo
Code 39Informationair-to-air
Indoor unit fan motor power supply error
Models concerned: Takao M2 wall-mounted R32
Code 51InformationAir-to-air
Indoor unit 1 fan motor error (Main fan)
Applicable models: Takao M2 wall-mounted R32
Code 59InformationAir-to-air
Indoor unit 2 fan motor error (Left-side fan)
Applicable models: Takao M2 wall-mounted R32
Code 5AInformationAir-to-air
Indoor unit 3 fan motor error (Right-side fan)
Applicable models: Takao M2 wall-mounted R32
Code 97InformationAir-to-water
Outdoor unit fan 1 error. — outdoor unit – LED 9 flashes / 7 flashes
Applicable models: Alfea Excellia, Alfea Excellia Duo
Code 97InformationAir-to-air
Outdoor unit fan motor error
Applicable models: Takao M2 wall-mounted R32
Code 98InformationAir-to-water
Outdoor unit fan 2 error. — outdoor unit – LED 9 flashes / 8 flashes
Applicable models: Alfea Excellia, Alfea Excellia Duo
Code 98InformationAir-to-air
Outdoor unit fan 2 motor error
Applicable models: Takao M2 wall-mounted R32
Code E6Medium severityAir-to-air
Phase reversal protection activated
Possible causes
  • Abnormal supply voltage
  • Incorrect electrical wiring
  • Faulty electronic board
Applicable models: Takao M2, Dojo, Nagano
This fault requires a qualified technician. Do not open the unit.

Communication — Atlantic

The indoor and outdoor units are no longer communicating. This is often due to the connecting cable or a circuit board, not the refrigerant circuit.

Code 1 FlashInformationAir-to-water
Serial communication feedback error. — diodes / LED
Applicable models: Alfea Excellia, Alfea Excellia Duo
Code 11InformationAir-to-air
Serial communication error
Applicable models: Takao M2 wall-mounted R32
This fault requires a qualified technician. Do not open the unit.
Code 18InformationAir-to-air
External communication error
Applicable models: Takao M2 wall-mounted R32
Code 30Medium severityAir-to-water
Communication fault between outdoor unit and controller
Possible causes
  • Communication cable between outdoor unit and controller
  • Electrical interference
  • Faulty controller board
What you can check
  • Check the wiring between the outdoor unit and the control panel
  • Turn off power for 30 minutes, then restart
Applicable models: Alfea Excellia, Alfea Extensa, Alfea M
This fault requires a qualified technician. Do not open the unit.
Code 32InformationAir-to-water
Communication error between the controller and the user interface. — outdoor unit – LED 3 flashes / 2 flashes
Applicable models: Alfea Excellia, Alfea Excellia Duo
Code 3AInformationAir-to-air
Communication circuit error between the indoor unit and wired remote control
Applicable models: Takao M2 wall-mounted R32
Code 62InformationAir-to-air
Outdoor unit main PCB model information error or communication error
Applicable models: Takao M2 wall-mounted R32
Code 6AInformationAir-to-air
Communication error between the display PCB microcomputers
Applicable models: Takao M2 wall-mounted R32

Power supply — Atlantic

The supply voltage is abnormal or missing. Check the dedicated circuit breaker first.

Code 31InformationAir-to-water
Hydraulic module power supply error. — outdoor unit – LED 3 flashes / 1 flash
Applicable models: Alfea Excellia, Alfea Excellia Duo
Code 31InformationAir-to-air
Power interruption error
Applicable models: Takao M2 wall-mounted R32
Code 370Informationair-to-water
Outdoor unit error (during a startup phase, see the “Commissioning” section).
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 61Informationair-to-water
Outdoor unit power supply error. — outdoor unit – LED 6 Flashes / 1 Flash
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 61Informationair-to-air
Wiring error, reversed or missing phases on the indoor unit
Affected models: Takao M2 wall-mounted R32
Code 67Informationair-to-water
Brief power outage to the outdoor unit (protection operation). — outdoor unit – LED 6 Flashes / 7 Flashes
Affected models: Alfea Excellia, Alfea Excellia Duo
Code A9Informationair-to-water
Overcurrent error. — outdoor unit – LED 10 Flashes / 9 Flashes
Affected models: Alfea Excellia, Alfea Excellia Duo

Discharge temperature — Atlantic

The compressor outlet temperature exceeds the safety threshold. This points to a refrigerant shortage or degraded heat exchange.

Code 11 FlashesInformationair-to-water
Discharge temperature protection (permanent shutdown). — diodes / LED
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 2 FlashesInformationair-to-water
Discharge temperature sensor error. — diodes / LED
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 71Informationair-to-water
Discharge temperature sensor error. — outdoor unit – LED 7 Flashes / 1 Flash
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 71Informationair-to-air
Discharge temperature sensor error
Affected models: Takao M2 wall-mounted R32
Code A1Informationair-to-water
Discharge temperature protection. — outdoor unit – LED 10 Flashes / 1 Flash
Affected models: Alfea Excellia, Alfea Excellia Duo
Code A1Informationair-to-air
Discharge temperature error
Affected models: Takao M2 wall-mounted R32

Filtration — Atlantic

Code 19 FlashesInformationair-to-water
Active filter error. — diodes / LED
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 55Informationair-to-air
Filter setting error
Affected models: Takao M2 wall-mounted R32
Code 64Informationair-to-water
Active filter error. — outdoor unit – LED 6 Flashes / 4 Flashes
Affected models: Alfea Excellia, Alfea Excellia Duo
Code 64Informationair-to-air
Active filter error and PFC error
Affected models: Takao M2 wall-mounted R32

Low pressure — Atlantic

The refrigerant circuit pressure is too low. This often indicates a refrigerant shortage, meaning a leak needs to be located.

Code 20 FlashesInformationair-to-water
Abnormal low pressure. — diodes / LED
Affected models: Alfea Excellia, Alfea Excellia Duo
This fault requires a qualified technician. Do not open the unit.
Code A5Informationair-to-water
Abnormal low pressure. — outdoor unit – LED 10 Flashes / 5 Flashes
Affected models: Alfea Excellia, Alfea Excellia Duo
This fault requires a qualified technician. Do not open the unit.
Code A5Informationair-to-air
Low pressure error
Affected models: Takao M2 wall-mounted R32
This fault requires a qualified technician. Do not open the unit.

High pressure — Atlantic

The refrigerant circuit pressure is too high. This is a safety feature: the unit shuts off before the compressor is damaged.

Code 86Informationair-to-air
• Discharge pressure sensor error • Suction pressure sensor error • High pressure switch error
Affected models: Takao M2 wall-mounted R32
This fault requires a qualified technician. Do not open the unit.
Code A4Informationair-to-air
High pressure error
Affected models: Takao M2 wall-mounted R32
This fault requires a qualified technician. Do not open the unit.
Code E8Critical severityair-to-air
Loss of communication between indoor unit / wired remote control (more than 4 min)
Possible causes
  • Damaged cable
  • Faulty indoor unit board
  • Defective wired remote control
Models affected: Takao M2, Dojo, Nagano

Power module — Atlantic

Code 18 FlashesInformationair-to-water
Inverter error. — diodes / LED
Models affected: Alfea Excellia, Alfea Excellia Duo
This fault requires a qualified technician. Do not open the unit.
Code 63Informationair-to-water
Inverter error. — outdoor unit – LED 6 Flashes / 3 Flashes
Models affected: Alfea Excellia, Alfea Excellia Duo
This fault requires a qualified technician. Do not open the unit.
Code 65Informationair-to-water
IPM board error. — outdoor unit – LED 6 Flashes / 5 Flashes
Models affected: Alfea Excellia, Alfea Excellia Duo

Electronic board — Atlantic

A control or power board is no longer responding. A full restart sometimes clears a false fault; otherwise a replacement is needed.

Code 32Informationair-to-air
Indoor unit PCB model information error
Models affected: Takao M2 wall-mounted R32
Code 62Informationair-to-water
Outdoor unit control board error. — outdoor unit – LED 6 Flashes / 2 Flashes
Models affected: Alfea Excellia, Alfea Excellia Duo

Expansion valve — Atlantic

The electronic expansion valve is no longer regulating refrigerant flow.

Code 9AInformationair-to-air
Expansion valve coil error
Models affected: Takao M2 wall-mounted R32

Circuit pressure — Atlantic

Code 28Medium severityair-to-water
Water pressure sensor fault (electronic pressure gauge)
Possible causes
  • Faulty water pressure sensor
  • Water pressure too low or too high
  • Faulty wiring
What you can check
  • Check the heating circuit pressure (1 to 2 bar)
  • Bleed the circuit if necessary
  • Cut power for 30 min, then restart
Models affected: Alfea Excellia, Alfea Extensa

Backup heater — Atlantic

Code 68Informationair-to-air
Outdoor unit current-limiting resistor temperature rise error
Models affected: Takao M2 wall-mounted R32

Reversing valve — Atlantic

Code 99Informationair-to-air
4-way valve error
Models affected: Takao M2 wall-mounted R32

All Atlantic codes published on the site

This list updates itself automatically with each new guide.

Technical information provided for guidance only, based on manufacturer documentation and field feedback. It does not replace a diagnosis by a qualified professional. Found an error on this page? Report it.