List of error codes for the Atlantic Dojo Mono and Multi-split air-to-air heat pump
List of error codes for the Atlantic Dojo Mono and Multi-split wall-mounted R32 air-to-air heat pump
Download the manual for the Atlantic Dojo Mono and Multi-split R32 air-to-air heat pump
Before you start, here are the most common error codes
- Error code 10 : outdoor sensor fault.
- Error code 50 : domestic hot water (DHW) temperature sensor fault.
- Error code 60 : room sensor 1 fault.
- Error code 121 : CC1 outlet temperature not reached.
- Error code 370 : outdoor unit error.
If you can’t find a solution to your problem, you can go directly to the Atlantic manufacturer’s website to look up your error code.
For the following models:
- AS 007 DB.UI
- AS 009 DB.UI
- AS 012 DB.UI
- AS 018 DB.UI
Turn off the power before starting any repair work
| Display on the indoor unit | Fault | Diagnosis |
| E1 | Room temperature sensor failure | Sensor unplugged, broken, or incorrectly positioned
Faulty circuit boards |
| E2 | Heat exchanger sensor failure | |
|
E4 |
EEPROM error on the indoor unit’s PCB | Incorrect EEPROM data, faulty EEPROM,
Indoor unit PCB failure |
|
E14 |
Fan motor malfunction |
Operation stopped due to a broken wire in the fan motor, Operation stopped due to broken fan motor wiring, Detection error caused by indoor unit circuit board failure |