All Toshiba error codes
Find your code quickly
The Toshiba codes on this page, grouped by type of fault.
Temperature sensor — Toshiba
These codes indicate a sensor that’s no longer returning a consistent value. The fault almost always comes from the sensor itself or its connector, rarely from the unit.
- Faulty outdoor coil thermistor
- Faulty wiring
- Cut the power for 30 minutes, then restart
- Faulty liquid-side thermistor
- Disconnected connector
- Sensor out of its housing
- Cut the power for 30 minutes, then restart
- Faulty gas-side thermistor
- Disconnected connector
- Damaged wiring
- Cut the power for 30 minutes, then restart
Circuit board — Toshiba
A control or power board is no longer responding. A full restart sometimes clears a false fault; otherwise, it needs replacing.
- Faulty indoor PCB
- Power surge
- Moisture on the board
- Cut the power for 30 minutes, then restart
- Corrupted EEPROM
- Power surge
- Faulty outdoor control board
- Cut the power for 30 minutes, then restart
General fault — Toshiba
These codes don’t point to a specific part: the unit is signaling that an internal safety feature has tripped.
- An indoor unit is powered off
- A unit’s connecting cable is cut
- Incorrect addressing of a unit
- Check that all indoor units are powered on
- Check the wiring of each unit
- Cut the main power for 30 minutes, then restart
- Outdoor unit configuration/addressing
Power supply — Toshiba
The supply voltage is abnormal or absent. Check the dedicated circuit breaker first.
- Missing phase
- Voltage out of range
- Blown fuse
- Phase reversal (three-phase)
- Check the electrical panel and fuses
- Have an electrician check the connection
Communication — Toshiba
The indoor unit and outdoor unit are no longer communicating. It’s often the connecting cable or a circuit board, not the refrigerant circuit.
- Remote control cable cut or loose
- Faulty wired remote control
- Interference on the line
- Check the remote control wiring
- Try using the infrared remote control instead
- Cut the power for 30 minutes, then restart
Compressor — Toshiba
The compressor is the central and most expensive part. These codes protect the unit by shutting it down before damage occurs: never force repeated restarts.
- Faulty power module
- Compressor struggling
- Damaged compressor wiring
- Cut the power — call a technician
Discharge temperature — Toshiba
The temperature at the compressor outlet exceeds the safety threshold. This points to low refrigerant or poor heat exchange.
- Refrigerant shortage (leak)
- Clogged filter dryer
- Blocked expansion valve
- Excessive high pressure
- Cut the power for 1 hour to let it cool down
- Clean the outdoor heat exchanger
- If the fault comes back: a leak is likely
All Toshiba codes published on the site
This list updates automatically with every new guide.