The LG codes on this page, grouped by failure type.

temperature sensor

161718198CH06CH67

compressor

CH26CH46

low pressure

6

discharge temperature

CH41

fan

CH53

Temperature Sensor — LG

These codes indicate a sensor that’s no longer returning a consistent value. The fault almost always comes from the sensor itself or its connector, rarely from the unit.

Code 16Informationair-to-water
Issue with the sensors
Affected models: Therma V
Code 17Informationair-to-water
Issue with the water inlet sensor
Affected models: Therma V
Code 18Informationair-to-water
Issue with the water outlet sensor
Affected models: Therma V
Code 19Informationair-to-water
Issue with the intermediate water sensor
Affected models: Therma V
Code 8Informationair-to-water
Issue with the water tank sensor
Affected models: Therma V
Code CH06Medium severityair-to-air
Indoor unit heat exchanger temperature sensor fault (outlet)
Possible causes
  • Faulty outlet thermistor
  • Disconnected connector
  • Displaced sensor
What you can check
  • Cut power for 30 minutes, then restart
Affected models: Standard Plus, ARTCOOL, Dualcool, Libero
This issue requires a qualified technician. Do not open the unit.
Code CH67Medium severityair-to-air
Outdoor fan motor blockage (BLDC)
Possible causes
  • Faulty outdoor fan motor
  • Blocked blade (ice, obstruction)
  • Disconnected motor connector
  • Faulty outdoor control board
Affected models: Standard Plus, ARTCOOL, Dualcool
This issue requires a qualified technician. Do not open the unit.

Compressor — LG

The compressor is the main and most expensive component. These codes shut down the unit to protect it before damage occurs: never force repeated restarts.

Code CH26Critical severityair-to-air
Compressor rotor position error (cannot start)
Possible causes
  • Seized compressor
  • Faulty power module
  • Unbalanced pressure at startup
What you can check
  • Cut power for 1 hour, then try a single restart
Affected models: Standard Plus, ARTCOOL, Dualcool
This issue requires a qualified technician. Do not open the unit.
Code CH46Medium severityair-to-air
Compressor suction sensor fault
Possible causes
  • Faulty suction thermistor
  • Disconnected connector
  • Damaged wiring
What you can check
  • Cut power for 30 minutes, then restart
Affected models: Standard Plus, ARTCOOL, Dualcool
This issue requires a qualified technician. Do not open the unit.

Low Pressure — LG

The refrigerant circuit pressure is too low. This often indicates a refrigerant shortage, meaning there’s a leak to locate.

Code 6Informationair-to-water
Issue with the refrigerant sensor (outlet side)
Affected models: Therma V
This issue requires a qualified technician. Do not open the unit.

Discharge Temperature — LG

The compressor outlet temperature exceeds the safety threshold. This points to a refrigerant shortage or impaired heat exchange.

Code CH41Critical severityair-to-air
Compressor discharge sensor fault
Possible causes
  • Faulty discharge sensor
  • Disconnected connector
  • Actual compressor overheating
What you can check
  • Cut off the power — call a technician
Models affected: Standard Plus, ARTCOOL, Dualcool
This issue requires a qualified technician. Do not open the unit.

Fan — LG

The fan expels or draws in heat. If it’s blocked or faulty, pressure rises and triggers a shutdown.

Code CH53Medium severityair-to-air
Indoor/outdoor unit communication fault (detected by the outdoor unit)
Possible causes
  • Connecting cable poorly connected or cut
  • Faulty indoor or outdoor board
Models affected: Standard Plus, ARTCOOL, Dualcool
This issue requires a qualified technician. Do not open the unit.

All LG codes published on the site

This list updates itself automatically whenever a new guide is added.

Technical information provided for guidance only, based on manufacturer documentation and field feedback. It does not replace the diagnosis of a qualified professional. Found an error on this page? Report it.