Home › Brands › Chaffoteaux

All Chaffoteaux error codes

This page brings together Chaffoteaux error codes sorted by type of fault: what each code means, its likely causes, and what you can safely check before calling a professional.
Can’t find your Chaffoteaux code in the list?
Describe your issue to Cody. It identifies the code, tells you what’s happening, and what you can check yourself. If it doesn’t know the code, it looks it up in the manufacturer’s documentation.

Ask Cody ›

Find your code quickly

The Chaffoteaux codes on this page, grouped by type of fault.

communication

131516385253915

power module

173942931

reversing valve

907912947

low pressure

36918

circuit board

114

high pressure

1935

condensate drain

7919

water flow

956

expansion valve

908

discharge temperature

37

Power Supply — Chaffoteaux

The supply voltage is abnormal or absent. First, check the dedicated circuit breaker.

Code 10Informationair-to-water
Low AC supply voltage — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 11Informationair-to-water
Supply current overload — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 12Informationair-to-water
Supply voltage measurement error — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 43Informationair-to-water
Heat sink overheating — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 44Informationair-to-water
Low DC bus voltage at startup — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 45Informationair-to-water
DC bus overvoltage — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 46Informationair-to-water
Low DC bus voltage — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 47Informationair-to-water
Low AC supply voltage — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 48Informationair-to-water
AC supply overvoltage — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 5Informationair-to-water
AC supply phase fault — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 50Informationair-to-water
CETTE supply voltage measurement error — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 7 22Informationair-to-water
Zone 2 overheating
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 7 23Informationair-to-water
Zone 3 overheating
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 8Informationair-to-water
DC bus overvoltage — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 9Informationair-to-water
Low DC bus voltage — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 950Informationair-to-water
TD overheat error. Perform a reset. — TDM (hydraulic module)
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 951Informationair-to-water
TD overheat error — TDM (hydraulic module)
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.

Temperature sensor — Chaffoteaux

These codes indicate a sensor that’s no longer returning a consistent value. The fault almost always comes from the sensor itself or its connector, rarely from the unit.

Code 51Informationair-to-water
Heat sink temperature sensor error — Inverter board
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 7 01Informationair-to-water
Zone 1 flow sensor fault
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 7 02Informationair-to-water
Zone 2 flow sensor fault
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 7 03Informationair-to-water
Zone 3 flow sensor fault
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 7 11Informationair-to-water
Zone 1 return sensor fault
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 7 12Informationair-to-water
Zone 2 return sensor fault
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 7 13Informationair-to-water
Zone 3 return sensor fault
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 911Informationair-to-water
TE Sensor error — TDM (hydraulic module)
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 913Informationair-to-water
LWT Sensor error — TDM (hydraulic module)
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 914Informationair-to-water
TR Sensor error — TDM (hydraulic module)
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 916Informationair-to-water
TEO Sensor error — TDM (hydraulic module)
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 948Informationair-to-water
TD Sensor error — TDM (hydraulic module)
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 949Informationair-to-water
TS Sensor error — TDM (hydraulic module)
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 952Informationair-to-water
TO Sensor error — TDM (hydraulic module)
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S

Compressor — Chaffoteaux

The compressor is the central and most expensive part. These codes protect the unit by shutting it down before damage occurs: never force repeated restarts.

Code 18Informationair-to-water
Compressor type error — Inverter board
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 2Informationair-to-water
Compressor IPM overcurrent — Inverter board
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 3Informationair-to-water
Fault in the compressor startup sequence — Inverter board
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 4Informationair-to-water
Compressor current overcurrent — Inverter board
Models concerned: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 40Informationair-to-water
Compressor startup failure — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 41Informationair-to-water
Compressor current overload — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 49Informationair-to-water
compressor emergency shutdown — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 6Informationair-to-water
Measurement error on IPM Compressor current — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 905Informationair-to-water
Compressor Control Error — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 906Informationair-to-water
Compressor Control Error — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 953Informationair-to-water
Compressor oil heater control error — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.

Communication — Chaffoteaux

The indoor unit and outdoor unit have lost communication. It’s usually the connecting cable or a board, not the refrigerant circuit.

Code 13Informationair-to-water
Communication error with the board’s microprocessor — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 15Informationair-to-water
Internal communication error between the board’s microcontrollers — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 16Informationair-to-water
Communication error between the INVERTER board and the TDM board — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 38Informationair-to-water
Communication error on the INVERTER board — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 52Informationair-to-water
Internal communication error between the board’s microcontrollers — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 53Informationair-to-water
Communication error with the IDU control board — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 915Informationair-to-water
TDM communication error — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S

General fault — Chaffoteaux

These codes don’t point to a specific part: the unit is signaling that an internal safety feature has tripped.

Code 2Informationair-to-water
P2
What you can check
  • Smart Grid Inputs Config. Error incomplete
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 4Informationair-to-water
20*
What you can check
  • BUS power supply overload
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 9 38Informationair-to-water
Anode fault
What you can check
  • Check the anode connection
  • Check that there is water in the tank
  • Check the condition of the anode
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 917Informationair-to-water
“Heat pump icing: LWT and/or TR temperature too low. Perform a reset.” — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 922Informationair-to-water
Heat pump icing — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 954Informationair-to-water
Outdoor unit heating cord control error — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code HP POWER OFFInformationair-to-water
SERVICE RESET — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S

Fan — Chaffoteaux

The fan releases or captures heat. If it’s blocked or faulty, pressure rises and triggers a shutdown.

Code 21Informationair-to-water
Fan 1 startup failure — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 27Informationair-to-water
Fan 1 control error — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 29Informationair-to-water
Fan 2 startup failure — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 909Informationair-to-water
Fan stopped while unit is running — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 957Informationair-to-water
Heat pump fan type configuration error — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S

Power module — Chaffoteaux

Code 17Informationair-to-water
IPM module overheating — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 39Informationair-to-water
IPM overcurrent — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 42Informationair-to-water
IPM current measurement error — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 931Informationair-to-water
Inverter error — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.

Reversing valve — Chaffoteaux

Code 907Informationair-to-water
4-way valve control error — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 912Informationair-to-water
4-way valve error. Turn off the system to acknowledge the fault — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 947Informationair-to-water
4-way valve error — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S

Low pressure — Chaffoteaux

The refrigerant circuit pressure is too low. This often indicates a refrigerant shortage, meaning there’s a leak to locate.

Code 36Informationair-to-water
Low-pressure switch protection (shunt on the board) — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 918Informationair-to-water
Refrigerant recovery cycle error — TDM (hydraulic module)
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.

Electronic board — Chaffoteaux

A control or power board is no longer responding. A full restart sometimes clears a false fault; otherwise, it needs to be replaced.

Code 1Informationair-to-water
Heat sink overheating (INVERTER board) — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 14Informationair-to-water
INVERTER board heat sink temperature sensor error — Inverter board
Affected models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.

High pressure — Chaffoteaux

The refrigerant circuit pressure is too high. This is a safety feature: the unit shuts down before the compressor gets damaged.

Code 19Informationair-to-water
High-pressure protection — Inverter board
Applicable models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.
Code 35Informationair-to-water
High-pressure switch protection (jumper on the board) — Inverter board
Applicable models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.

Condensate drainage — Chaffoteaux

Code 7Informationair-to-water
Capacitor charging fault — Inverter board
Applicable models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
Code 919Informationair-to-water
Condensing temperature too high error — TDM (hydraulic module)
Applicable models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S

Water flow — Chaffoteaux

The water flow in the heating circuit is insufficient. The usual suspects are the circulator pump, filter, valves, and air in the system.

Code 956Informationair-to-water
Insufficient flow error — TDM (hydraulic module)
Applicable models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S

Expansion valve — Chaffoteaux

The electronic expansion valve is no longer regulating the refrigerant flow.

Code 908Informationair-to-water
Gas expansion valve control error — TDM (hydraulic module)
Applicable models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S

Discharge temperature — Chaffoteaux

The compressor outlet temperature exceeds the safety threshold. This points to low refrigerant charge or poor heat exchange.

Code 37Informationair-to-water
Compressor overheat thermostat protection (jumper on the board) — Inverter board
Applicable models: Arianext Compact M, Arianext Compact S, Arianext Flex M, Arianext Plus M, Arianext Flex S, Arianext Plus S
This fault requires a qualified technician. Do not open the unit.

All Chaffoteaux codes published on the site

This list updates automatically whenever a new guide is added.

Technical information provided for guidance only, based on manufacturer documentation and field reports. It does not replace the diagnosis of a qualified professional. Found an error on this page? Report it.