List of error codes for the Chaffoteaux Arianext Compact M air-to-water heat pump
List of indoor unit error codes – Chaffoteaux Arianext Compact M
Download the manual for the Chaffoteaux Arianext Compact M
| ERROR CODE | DESCRIPTION | TROUBLESHOOTING | |
| 1 | 14 | Outdoor sensor fault | – Activation of weather compensation based on the outdoor sensor.
– Outdoor sensor not connected or damaged. |
| 4 | 20* | BUS power supply overload | |
| 7 | 01 | Zone 1 flow sensor fault | |
| 7 | 02 | Zone 2 flow sensor fault | |
| 7 | 03 | Zone 3 flow sensor fault | |
| 7 | 11 | Zone 1 return sensor fault | |
| 7 | 12 | Zone 2 return sensor fault | |
| 7 | 13 | Zone 3 return sensor fault | |
| 7 | 22 | Zone 2 overheating | |
| 7 | 23 | Zone 3 overheating | |
| 9 | 02 | Flow temperature sensor fault | Flow sensor not connected or faulty |
| 9 | 03 | Return temperature sensor fault | Return sensor not connected or faulty |
| 9 | 10 | Heat pump communication error | – Check the Modbus connection cable
– Red LED steady on -> replace the TDM board |
| 9 | 23 | Heating circuit pressure fault | – Check for water leaks in the hydraulic circuit
– Faulty pressure switch – Faulty pressure switch wiring |
| 9 | 24 | No communication with the heat pump | – Check the wiring between the TDM board and the Energy Manager |
| 9 | 33 | Primary circuit overheating | – Check the flow rate in the primary circuit |
| 9 | 34 | Tank sensor fault | – Tank sensor not connected or faulty |
| 9 | 35 | High tank temperature | – Check whether the 3-way valve is stuck in the DHW position |
| 9 | 36 | Underfloor heating thermostat open | – Check the flow rate of the underfloor heating system |
| 9 | 37 | Circulation error | – Check that the main circulator pump is activated
– Check the flow rate using parameter 17.11.3 |
| 9 | 38 | Anode fault | – Check the anode connection
– Check that there is water in the tank – Check the condition of the anode |
| 9 | 39 | Heat pump error ** | See the Inverter error list |
| 9 | 40 | Hydraulic diagram not defined | Hydraulic diagram not selected via parameter 17.2.0 |
| 9 | 41 | Peak/Off-Peak hours not defined | Function not selected via parameter 17.1.0 |
| 9 | 42 | Load shedding contact not defined | Function not selected via parameter 17.1.1 |
| 9 | 44 | Overheating in cooling mode | Check the flow rate in the cooling circuit |
| 9 | 45 | Flow switch stuck | – Check whether the main circulator pump is activated before the heat demand
– Check the flow rate using the flow meter value via parameter 17.11.3 |
| 9 | 46 | Heat pump compressor fault | Check the compressor frequency after the end of the heat demand using
parameter 17.12.1 |
| 9 | 55 | Insufficient flow error | Check the flow rate using the flow meter value via parameter 17.11.3
during heat demand |
|
2 |
P2 |
Anti-bacteria cycle not completed |
Thermal disinfection temperature not reached within 6 hours:
– Check the domestic hot water draw-off during the thermal disinfection cycle – Check the domestic hot water flow rate during the thermal disinfection cycle – Check that the electric heating element is turning on |
|
2 |
P3 |
DHW BOOST function: temperature not reached |
– Domestic hot water setpoint temperature not reached during the boost cycle
– Check the domestic hot water level during the DHW boost cycle – Check the domestic hot water flow rate during the DHW boost cycle – Check that the electric heating element is turning on |
| 2 | P4 | Backup heating element thermostat (auto) | – Check that the main circulator pump is activated
– Check the flow rate using the flow meter value via parameter 17.11.3 – Check the condition of the safety thermostat and wiring |
| 2 | P5 | Backup heating element thermostat (manual) | – Check that the main circulator pump is activated
– Check the flow rate using the flow meter value via parameter 17.11.3 – Check the condition of the safety thermostat and wiring |
| 2 | P6 | Night rate not present | Parameter 17.5.2 = HP-HC or HP-HC 40°C and parameter 17.1.0 = absent |
| 2 | P7 | Pre-circulation error | Flow not measured for 5 minutes during pre-circulation |
| 2 | P9 | Incomplete Smart Grid input configuration error | Only one of parameters 17.1.0 or 17.1.1 is set as the SG Ready input |
(*) BUS power supply overload
A BUS power supply overload error can occur when three or more devices are connected within the installed system. The devices that can cause a BUS network overload are:
- Multizone module
- Solar pump station
- Instant domestic hot water production module. To avoid any risk of BUS power supply overload, switch microswitch 1 on one of the electronic boards present in the devices connected to the system (except the boiler) to the OFF position, as shown.
(**) Error code table
The system is protected by internal checks carried out by the electronic board, which shuts the system down whenever a malfunction occurs.
List of outdoor unit error codes – Chaffoteaux Arianext Plus S
|
ERROR TDM |
DESCRIPTION |
RESET | |
| HP POWER OFF | SERVICE RESET | ||
| 905 | Compressor control error | x | |
| 906 | Compressor control error | x | |
| 907 | 4-way valve control error | x | |
| 908 | Gas expansion valve control error | x | |
| 909 | Fan stopped while unit is
running |
x | |
| 947 | 4-way valve error | x | |
| 912 | 4-way valve error.
Turn the system off to clear the fault |
x | |
| 948 | TD sensor error | — | — |
| 949 | TS sensor error | — | — |
| 911 | TE sensor error | — | — |
| 952 | TO sensor error | — | — |
| 913 | LWT sensor error | — | — |
| 914 | TR sensor error | — | — |
| 916 | TEO sensor error | — | — |
| 915 | TDM communication error | — | — |
| 953 | Compressor oil heater control
error |
— | — |
| 954 | Outdoor unit heating cable control
error |
— | — |
| 956 | Insufficient flow error | — | — |
| 957 | Heat pump fan type
configuration error |
— | — |
| 922 | Heat pump frost formation | x | |
| 917 | “Heat pump frost formation: LWT and/or TR temperature too low. Perform a
reset.” |
— | x |
| 951 | TD overheating error | x | |
| 950 | TD overheating error. Perform a
reset. |
— | x |
| 918 | Refrigerant recovery cycle
error |
— | — |
| 919 | Condensing temperature
too high error |
x | |
| 931 | Inverter Error | — | — |
| ERROR INVERTER | DESCRIPTION | 1ph | 3ph |
| 1 | Overheating of the heat sink (INVERTER
board) |
x | x |
| 2 | Compressor IPM overcurrent | x | |
| 3 | Fault in the compressor startup
sequence |
x | |
| 4 | Compressor current overcurrent | x | x |
| 5 | Phase fault on the AC power supply | x | |
| 6 | Measurement error on the compressor IPM
current |
x | |
| 7 | Capacitor charging fault | x | |
| 8 | DC bus overvoltage | x | |
| 9 | Low DC bus voltage | x | |
| 10 | Low AC supply voltage | x | |
| 11 | Supply current overcurrent | x | |
| 12 | Error measuring the supply voltage | x | |
| 13 | Communication error with the board’s
microprocessor |
x | |
| 14 | Error on the INVERTER board heat sink
temperature sensor |
x | |
| 15 | Internal communication error between the
board’s microcontrollers |
x | |
| 16 | Communication error between the INVERTER
board and the TDM board |
x | |
| 17 | IPM module overheating | x | |
| 18 | Compressor type error | x | x |
| 19 | High pressure protection | x | x |
| 21 | Fan 1 startup failure | x | |
| 27 | Fan 1 control error | x | |
| 29 | Fan 2 startup failure | x | |
| 35 | High pressure switch protection (shunted
on the board) |
x | x |
| 36 | Low pressure switch protection
(shunted on the board) |
x | x |
| 37 | Compressor overheat thermostat protection
(shunted on the board) |
x | x |
| 38 | Communication error on the INVERTER board | x | |
| 39 | IPM overcurrent | x | |
| 40 | Compressor startup failure | x | |
| 41 | Compressor current overcurrent | x | |
| 42 | IPM current measurement error | x | |
| 43 | Heat sink overheating | x | |
| 44 | Low DC bus voltage at startup | x | |
| 45 | DC bus overvoltage | x | |
| 46 | Low DC bus voltage | x | |
| 47 | Low AC supply voltage | x | |
| 48 | AC supply overvoltage | x | |
| 49 | emergency compressor shutdown | x | |
| 50 | Supply voltage measurement error
THIS |
x | |
| 51 | Heat sink temperature sensor error | x | |
| 52 | Internal communication error between
the board’s microcontrollers |
x | |
| 53 | Communication error with the IDU
control board |
x |