List of error codes for the Chaffoteaux Arianext Compact S air-to-water heat pump

List of indoor unit error codes – Chaffoteaux Arianext Compact S

Download the Chaffoteaux Arianext Compact S manual

ERROR CODE DESCRIPTION TROUBLESHOOTING
1 14 Outdoor sensor fault – Activation of weather compensation based on the outdoor sensor.

– Outdoor sensor not connected or damaged.

4 20* BUS power supply overload
7 01 Zone 1 flow sensor fault
7 02 Zone 2 flow sensor fault
7 03 Zone 3 flow sensor fault
7 11 Zone 1 return sensor fault
7 12 Zone 2 return sensor fault
7 13 Zone 3 return sensor fault
7 22 Zone 2 overheating
7 23 Zone 3 overheating
9 02 Flow temperature sensor fault Flow sensor not connected or faulty
9 03 Return temperature sensor fault Return sensor not connected or faulty
9 10 Heat pump communication error – Check the Modbus connection cable

– Red LED steadily on -> replace the TDM board

9 23 Heating circuit pressure fault – Check for water leaks in the hydraulic circuit

– Faulty pressure switch

– Faulty pressure switch wiring

9 24 No communication with the heat pump – Check the wiring between the TDM board and the Energy Manager
9 33 Primary circuit overheating – Check the flow in the primary circuit
9 34 Tank sensor fault – Tank sensor not connected or faulty
9 35 High tank temperature – Check whether the 3-way valve is stuck in the DHW position
9 36 Floor thermostat open – Check the flow in the underfloor heating system
9 37 Circulation error – Check that the main circulator pump is activated

– Check the flow using parameter 17.11.3

9 38 Anode fault – Check the anode connection

– Check for water in the tank

– Check the condition of the anode

9 39 Heat pump error ** See the Inverter error list
9 40 Hydraulic diagram not defined Hydraulic diagram not selected via parameter 17.2.0
9 41 Peak/off-peak hours not defined Function not selected via parameter 17.1.0
9 42 Load-shedding contact not defined Function not selected via parameter 17.1.1
9 44 Overheating in cooling mode Check the flow in the cooling circuit
9 45 Flow switch stuck – Check whether the main circulator pump is activated before the heat demand

– Check the flow against the flow meter value using parameter 17.11.3

9 46 Heat pump compressor fault Check the compressor frequency after the heat demand ends,

using parameter 17.12.1

9 55 Insufficient flow error Check the flow against the flow meter value using parameter 17.11.3

during the heat demand

 

2

 

P2

 

Anti-bacteria cycle not completed

Thermal disinfection temperature not reached within 6 hours:

– Check domestic hot water draw-off during the thermal disinfection cycle

– Check the domestic hot water flow during the thermal disinfection cycle

– Check that the electric heating element is turning on

 

2

 

P3

 

DHW BOOST function: temperature not reached

– Domestic hot water setpoint temperature not reached during the boost cycle

– Check the domestic hot water level during the DHW boost cycle

– Check the domestic hot water flow during the DHW boost cycle

– Check that the electric heating element is turning on

2 P4 Backup heater thermostat (auto) – Check that the main circulator pump is activated

– Check the flow against the flow meter value using parameter 17.11.3

– Check the condition of the safety thermostat and its wiring

2 P5 Backup heater thermostat (manual) – Check that the main circulator pump is activated

– Check the flow against the flow meter value using parameter 17.11.3

– Check the condition of the safety thermostat and its wiring

2 P6 Night rate not present Parameter 17.5.2 = HP-HC or HP-HC 40°C and parameter 17.1.0 = absent
2 P7 Pre-circulation error Flow not detected for 5 minutes during pre-circulation
2 P9 Smart Grid input configuration incomplete error Only one of parameters 17.1.0 or 17.1.1 is set as the SG Ready input

(*) BUS power supply overload

A BUS power supply overload error can occur when three or more devices are connected within the installed system. Devices that can cause a BUS network overload include:

  • Multizone module
  • Solar pump group
  • Instant domestic hot water production module. To avoid any risk of BUS power supply overload, switch microswitch 1 on one of the electronic boards present in the devices connected to the system (except the boiler) to the OFF position, as shown.

(**) Error code table

The system is protected by internal checks performed by the electronic board, which shuts the system down whenever a malfunction occurs.

List of outdoor unit error codes – Chaffoteaux Arianext Plus S

 

ERROR TDM

 

DESCRIPTION

RESET
HP POWER OFF SERVICE RESET
905 Compressor control error x
906 Compressor control error x
907 4-way valve control error x
908 Gas expansion valve control error x
909 Fan stopped while unit is

running

x
947 4-way valve error x
912 4-way valve error.

Turn the system off to clear

the fault

x
948 TD sensor error — —
949 TS sensor error — —
911 TE sensor error — —
952 TO sensor error — —
913 LWT sensor error — —
914 TR sensor error — —
916 TEO sensor error — —
915 TDM communication error — —
953 Compressor oil heater control

error

— —
954 Outdoor unit heating cable control

error

— —
956 Insufficient flow error — —
957 Heat pump fan type

configuration error

— —
922 Heat pump frost formation x
917 “Heat pump frost formation: LWT and/or TR temperature too low. Perform a

reset.”

— x
951 TD overheating error x
950 TD overheating error. Perform a

reset.

— x
918 Refrigerant recovery cycle

error

— —
919 Condensing temperature

too high error

x
931 Inverter Error — —
ERROR INVERTER DESCRIPTION 1ph 3ph
1 Heat sink overheating (INVERTER

board)

x x
2 Compressor IPM Overcurrent x
3 Fault in the compressor startup

sequence

x
4 Compressor current overload x x
5 AC power supply phase fault x
6 Measurement error on IPM Com-

pressor current

x
7 Capacitor charging fault x
8 DC bus overvoltage x
9 Low DC bus voltage x
10 Low AC supply voltage x
11 Supply current overload x
12 Error measuring supply voltage x
13 Communication error with the board’s

Microprocessor

x
14 Error on the INVERTER board heat sink

temperature sensor

x
15 Internal communication error between the

board’s microcontrollers

x
16 Communication error between the INVERTER board

and the TDM board

x
17 IPM module overheating x
18 Compressor type error x x
19 High-pressure protection triggered x x
21 Fan 1 startup failure x
27 Fan 1 control error x
29 Fan 2 startup failure x
35 High-pressure switch protection (shunt

on the board)

x x
36 Low-pressure switch protection

(shunt on the board)

x x
37 Compressor overheat thermostat protection

(shunt on the board)

x x
38 Communication error on the INVERTER board x
39 IPM Overcurrent x
40 Compressor startup failure x
41 Compressor current overload x
42 IPM current measurement error x
43 Heat sink overheating x
44 Low DC bus voltage at startup x
45 DC bus overvoltage x
46 Low DC bus voltage x
47 Low AC supply voltage x
48 AC supply overvoltage x
49 Compressor emergency shutdown x
50 Error measuring supply voltage

THIS

x
51 Heat sink temperature sensor error x
52 Internal communication error between

the board’s microcontrollers

x
53 Communication error with the IDU

control board

x