List of error codes for the Panasonic Aquarea T-CAP H Series air-to-water heat pump

List of error codes for the air-to-water heat pump – Panasonic Aquarea T-CAP H Series

Download the manual for the Panasonic Aquarea T-CAP H Series air-to-water heat pump

Turn off the power before troubleshooting

Symptom Cause
You hear the sound of water flowing during operation. •Refrigerant flowing inside the unit.
Operation slows down a few minutes after restarting the unit. •This slowdown is a compressor protection feature.
The outdoor unit gives off steam or water. •Condensation or evaporation occurring in the pipes.
Steam comes out of the outdoor unit in heating mode. •This is caused by the defrost operation of the heat exchanger.
The outdoor unit does not operate. •This is caused by the system’s protection control when the outdoor temperature is outside the operating range.
The system stops operating. •This is caused by the system’s protection control. When the water inlet temperature is below 10°C, the compressor stops and the backup heater turns on.
The system is slow to heat up. •When the panel and floor are heated at the same time, the hot water temperature may drop, which can reduce the system’s heating capacity.

•When the outdoor air temperature is low, the system may need more time to heat up.

•The outdoor unit’s exhaust or intake is blocked by an obstruction, such as a buildup of snow.

•When the preset water outlet temperature is low, the system may need more time to heat up.

The system does not heat up instantly. •The system will take some time to heat the water if it starts operating with cold water.
The electric backup heater turns off automatically when disabled. •This is caused by the indoor unit’s heat exchanger protection control.
The system starts operating automatically when the Clock is not set. •The sterilization program has been set.
Loud refrigerant noises continue to be heard for several minutes. •These are caused by the protection control during defrost operation at an outdoor ambient temperature below -10°C.
*1 COOL mode is unavailable. •The system is locked to operate in HEAT mode only.

 

Check the following before calling for service.

Symptom Check
HEAT/*1 COOL mode does not work efficiently. •Set the temperature correctly.

•Close the heating/cooling panel valve.

•Clear any obstructions from the outdoor unit’s air intake and outlet vents.

The unit makes noise during operation. •The outdoor or indoor unit was installed at a slant.

•Close the cover properly.

The system does not operate. •The circuit breaker is tripped/activated.
The operation indicator is not lit, or nothing is displayed on the remote control. •Check whether the power supply is working properly or if there has been a power outage.

 

*1 The system is locked to operate without COOL mode. It can only be unlocked by our authorized installers or our authorized

service centers.

*2 Only displayed when COOL mode is unlocked (i.e., when COOL mode is available).

Error codes

H12 Incompatible capacity
H15 Compressor sensor fault
H20 Circulator pump fault
H23 Refrigerant sensor fault
H27 Service valve fault
H28 Solar sensor fault
H31 Pool sensor fault
H36 Buffer tank sensor fault
H38 Brand compatibility fault
H42 Low pressure protection
H43 Zone 1 sensor fault
H44 Zone 2 sensor fault
H62 Water flow fault
H63 Low pressure sensor fault
H64 High pressure sensor fault
H65 Defrost water circulation error
H67 Outdoor thermistor fault 1
H68 Outdoor thermistor fault 2
H70 Heating element OLP fault
H72 DHW tank sensor fault
H74 Board communication fault
H75 Low water temperature protection
H76 Remote control-indoor unit communication fault
H90 Indoor/outdoor communication fault
H91 DHW tank heating element OLP fault
H95 Power supply wiring fault
H98 High pressure protection
H99 Indoor freeze prevention

 

F12 Pressure switch activated
F14 Compressor rotation fault
F15 Blocked fan motor fault
F16 Current protection
F20 Compressor overload protection
F22 Module transistor overload protection
F23 DC PIC fault
F24 Refrigerant cycle fault
F25 *1 Heating/cooling cycle fault
F27 Pressure switch fault
F29 Low flow overheat
F30 Water outlet sensor fault :2
F32 Internal thermostat fault
F36 Outdoor sensor fault
F37 Water return sensor fault
F40 Outdoor discharge sensor fault
F41 Power factor correction fault
F42 Heat exchanger outdoor sensor fault
F43 Outdoor defrost sensor fault
F45 Water outlet sensor fault
F46 Current transformer disconnection
F48 Evaporator outlet sensor fault
F49 Bypass outlet sensor fault
F95 *1 High pressure fault in cooling